FG Wilson Diesel Power Generator P7.5-1S, 6.8 kW - 7.5 kW without Housing
zoom_out_map
chevron_left chevron_right

FG Wilson Diesel Power Generator P7.5-1S, 6.8 kW - 7.5 kW without Housing

The FG Wilson Power Generator Diesel P7.5-1S delivers a dependable and robust power solution, generating between 6.8 kW and 7.5 kW of electricity. This particular model comes without a housing, providing flexibility for its integration into various applications. Built for durability and efficiency, this powerful generator serves as an excellent choice for a wide range of energy requirements and environments.
100% secure payments

Anatolii Livashevskyi
Product Manager
Українська / Polski
+48721808900
+48721808900
Telegram +48721808900
[email protected]

Olesia Ushakova
Product Manager
Українська / Polski
+48695005004
+48695005004
Telegram +48695005004
[email protected]

Description

P7.5-1S Generator Set

Benefits

Up To 2000L Extended Capacity Fuel Tanks

Larger fuel tanks allow for longer periods of time between refueling

As Low As 57 dBA Super silent enclosures

Super Silent enclosures offer excellent sound attenuation with sound as low as 57 dBA at 7m

Stay In Control Telematics Ready

Telematics availability allows for remote access to genset controls ensuring your always in control were ever you are



Product Specifications For P7.5-1S

Generator Set Specifications

Minimum Rating 6.8 kVA / 6.8 kW

Maximum Rating 7.5 kVA / 7.5 kW

Emissions/Fuel Strategy Fuel Optimised

50 Hz Prime 6.8 kVA / 6.8 kW

50 Hz Standby 7.5 kVA / 7.5 kW

60 Hz Prime - / -

60 Hz Standby

Frequency 50 Hz

Speed 1500 RPM

Voltage 230-240 Volts

50 Hz Prime Rating These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

60 Hz Prime Rating These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).

50 Hz Standby Rating Standard reference conditions 25°C (77°F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.

Engine Specifications

Engine Model Perkins® 403A-11G1

Bore 77 mm (3 in)

Stroke 81 mm (3.2 in)

Governor Type Mechanical

Displacement 1.1l (69 cu. in)

Compression Ratio 23:01

Data sheet

K830TNS85F

Buy a generator in Poland

The cost of delivery is calculated according to the place of delivery in Poland, Ukraine and European Union.